PRODUCT SPECIFICATIONS

DINSTAR DAG2000-16S 16-Port FXS Analog VoIP Gateway

The DINSTAR DAG2000-16S connects existing analog telephones and fax machines to SIP-based IP telephony networks. Its 16 RJ11 FXS ports provide analog endpoint connections, allowing businesses to retain suitable legacy devices while moving their telephone services to VoIP.

Designed for small and medium businesses, call centers and branch deployments, the gateway supports SIP signaling, IPv4 and IPv6, flexible dial plans and fax over IP. The version described here includes three 10/100 Mbps RJ45 Ethernet interfaces.

Key Features

  • 16 FXS analog telephone ports with RJ11 connectors.
  • Three 10/100 Mbps RJ45 Ethernet interfaces.
  • SIP v2.0 support with primary and backup SIP server configuration.
  • T.38 fax relay and fax pass-through.
  • IPv4 and IPv6 networking.
  • SIP TLS and SRTP support.
  • 802.1Q VLAN tagging, 802.1p prioritization and Layer 3 QoS.
  • SNMP, TR-069 and automatic provisioning.
  • Web-based configuration, diagnostic tools and configuration backup.

Analog Telephone Integration

The FXS interfaces connect to suitable analog telephones, fax machines or FXO trunk interfaces on a compatible legacy PBX. Supported analog functions include DTMF and pulse dialing, DTMF/FSK caller ID presentation, polarity reversal and programmable call progress tones.

Important: These are FXS ports for analog endpoint connections. They are not FXO ports for connecting incoming analog PSTN lines.

Voice and Fax

The gateway supports voice codecs including G.711 A-law and µ-law, G.723.1, G.729A/B, G.726, AMR and iLBC. Voice processing includes echo cancellation, an adaptive jitter buffer, voice activity detection and comfort noise generation.

Fax support includes T.38 and pass-through, with a documented fax rate of up to 14.4 kbps. Successful fax operation also depends on the remote equipment, service provider and network configuration.

SIP Connectivity and Call Features

SIP connectivity supports integration with suitably configured IP PBXs, SIP servers and service platforms. Available call functions include call waiting, hold, blind and attended transfer, forwarding, do-not-disturb, hunting groups and three-way conferencing.

Network Management

Administrators can use web configuration, SNMP and TR-069 to manage supported deployments. Maintenance tools include configuration backup and restore, firmware upgrades, call detail records, syslog, network capture and connectivity tests.

Power and Installation

The documented AC power input is 100–240V AC at 50–60 Hz, with typical consumption of 30W. The unit measures 440 × 230 × 44 mm and is specified for operation from 0°C to 45°C.

Ideal Applications

  • Connecting existing analog telephones to a SIP-based telephone system.
  • Retaining supported fax machines during a VoIP migration.
  • Adding analog endpoint connectivity at offices and branches.
  • Integrating compatible legacy PBX FXO trunk interfaces with IP telephony.

Compatible Products

The DAG2000-16S supports the following equipment categories when their electrical and signaling requirements match:

  • Analog telephones: Standard analog endpoints designed to connect to an FXS telephone interface.
  • Analog fax machines: Devices supported through properly configured T.38 or fax pass-through connections.
  • Legacy analog PBXs: Systems with suitable FXO trunk interfaces that can connect to the gateway's FXS ports.
  • SIP-based IP PBXs and SIP servers: Systems with compatible SIP signaling, authentication, codecs, DTMF handling and routing configuration.

Important: Do not connect an active PSTN telephone line or another FXS source to this gateway's FXS ports. Incoming analog telephone lines require an appropriate FXO gateway.

Important: Digital proprietary PBX handsets are not equivalent to standard analog telephones, even when they use a similar modular connector.

Important: SIP compatibility requires matching server and gateway settings. Fax, encryption and supplementary call features also require support from the other endpoint or service platform.

Technical Specifications

General

  • Brand: DINSTAR
  • Model / MPN: DAG2000-16S
  • Product Type: FXS analog VoIP gateway

Analog Interfaces

  • FXS Ports: 16
  • Analog Connectors: RJ11
  • Dialing: DTMF and pulse
  • Pulse Dialing Rates: 10 and 20 pulses per second
  • Caller ID: DTMF/FSK presentation
  • Additional Functions: Polarity reversal, hook flash and programmable call progress tones

Ethernet and Console

  • Ethernet Interfaces: 3 × 10/100 Mbps RJ45 LAN ports
  • Console: 1 × RS232
  • Console Rate: 115200 bps

VoIP and Security

  • SIP: SIP v2.0, RFC 3261, UDP/TCP
  • Secure Signaling and Media: SIP TLS and SRTP
  • Media Transport: RTP/RTCP
  • Server Functions: Primary/backup SIP server, outbound proxy and SIP trunk support
  • NAT Functions: STUN, rport and static/dynamic NAT support

Voice and Fax

  • Voice Codecs: G.711 A-law/µ-law, G.723.1, G.729A/B, G.726, AMR and iLBC
  • Echo Cancellation: G.168, up to 128 ms
  • Voice Processing: Adaptive jitter buffer, silence suppression, VAD and comfort noise generation
  • Fax: T.38 and pass-through
  • Documented Fax Rate: Up to 14.4 kbps
  • DTMF Methods: SIP signaling, RFC 2833 and in-band

Networking and QoS

  • IP Support: IPv4 and IPv6
  • Additional Networking: PPPoE
  • VLAN: IEEE 802.1Q, with voice/data/management VLAN support
  • Traffic Prioritization: IEEE 802.1p, Layer 3 QoS and DiffServ
  • Dialing and Routing: Digit maps, prefix-based routing and caller/called number manipulation

Management

  • Management Protocols: SNMP v1/v2/v3 and TR-069
  • Provisioning: Automatic provisioning
  • Administration: Web interface, configuration backup/restore and firmware upgrades
  • Diagnostics: CDR, syslog, ping, traceroute and network capture

Power

  • Power Input: 100–240V AC, 50–60 Hz
  • Typical Power Consumption: 30W

Physical and Environmental

  • Dimensions, W × D × H: 440 × 230 × 44 mm
  • Unit Weight: 2.7 kg
  • Operating Temperature: 0°C to 45°C
  • Storage Temperature: -20°C to 80°C
  • Humidity: 10%–90%, non-condensing

Compliance

  • CE
  • FCC