PRODUCT SPECIFICATIONS

The TP-DCDC-4848GD-HP offered by Tycon Power is a low cost and high efficiency solution for those requiring IEEE802.3af and IEEE802.3at Power over Ethernet from a 48VDC voltage source like a battery system or vehicle. They have an integrated POE injector to apply the power and data output to the CAT5/6 Ethernet cable. The output voltage is regulated and protected. They have a common (-) and two (+) inputs for connecting 2 power sources, such as a primary with a backup power source.

They accept gigabit data-in to a shielded RJ45 Jack and provide gigabit data-out and PoE power on the shielded RJ45 output jack. They work by supplying power on Ethernet pins 4,5(V+) and 7,8(V-). They have various protections for surge, short circuit and overload. The units have power outputs up to 50W.

Features

  • Input Voltage 48VDC (Range 36-72VDC)
  • IEEE 802.3af/at Compliant
  • Dual Inputs for Connecting 2 Power Sources
  • Integrated 10/100/1000MB PoE Inserter
  • High Power up to 35W
  • Low Self Consumption Power
  • Short Circuit, Over Current and Reverse/Over Voltage Protect
  • High Temperature Operation
  • Compact Size – Maximize Available Space
  • I.T.E. Power Supply, CE Listed

Applications

  • 48V Battery Systems, Vehicle Applications
  • Wireless Access Points and Client Devices
  • IP Phone and Security Camera Systems
  • PoE Lighting Applications

Dimensions (LxWxH)

  • 85 x 76 x 36mm (3.4 x 3 x 1.4”)

Weight

  • 134g (4.7oz)

Technical Description

  • DC Input Voltage: +/- 36 to 72VDC
  • DC Input Connector: Removeable Screw Type Compression Wire Terminal (12 AWG Max)
  • DC Output Voltage: 48V (802.3af)
  • Data in & Data/POE Output Connector: RJ45 (Shielded)
  • Output Current (max): 0.35A
  • Output Power (max): 17W
  • Isolation: PRI to SEC 1500VDC, SEC to GND 500VDC
  • Self Consumption Power: <1W
  • Efficiency (min): 75%
  • Line Regulation: 1%
  • Load Regulation: 5%
  • Ripple: 1%
  • Noise: 1%
  • EMC Standards: FCC Class B EN55022 Class B
  • Safety Standards: CSA 22.2 &TUV EN60950
  • Operating Temp: -30 to +60°C (-22 to +140°F)
  • Operating Humidity: 5% - 90%
  • Storage Temp: -40 to +80°C (-40 to +176°F)
  • MTBF (Mean Time Between Failure): 111,863 Hours