PRODUCT SPECIFICATIONS
Tycon TP-POE-HP-56G-FBN PoE Power Sources
The TP-POE-HP-56G-FBN Power over Ethernet Power Source offered by Tycon Power® is a quality midspan power source for years of reliable operation even in the toughest conditions. They accept data-in to a shielded RJ45 Jack and provide surge protected data-out and power on the shielded RJ45 output jack. They work by supplying power to the remote device on all 8 Ethernet pins. The Ethernet spec supports distances up to 100m (328 feet).
The units are autoranging so that they accept AC inputs from 90VAC to 264VAC (50/60 Hz) and they supply regulated DC Voltage at the output. They have various protections for surge, short circuit, overload and overvoltage. The TP-POE-HP-56G-FBN has an output power of 60watts. The output voltage is 56VDC with load regulation within 5%. The units can be DIN rail mounted.
Key Features
- Remotely Power Equipment thru CAT5 Cable up to 100m
- Built in Ethernet and AC Surge Protection
- Autoranging Switching Power Supply
- Short Circuit, Over Current and Over Voltage Protection
- High Power to 60W PoE Output
- 10/100/1000Mb Gigabit Compatible
- High Temperature Operation to 60C
- DIN Rail Mountable
- Wireless Access Points and Client Devices
- IP Phone and Security Camera Systems
Technical Description
- AC Input: 90-264VAC 47-63Hz
- Max Inrush Current (120VAC): 25A
- POE Voltage: 56VDC @ 1.07A
- Output Power: 60W Max
- Efficiency (min): 80%
- Line/ Load Regulation: 1% / 5%
- Ripple/ Noise: 1% / 2%
- POE Compatibility Passive: PoE
- Data Compatibility: 10/100/1000M , Gigabit Compatible
- Protections: Over-Voltage, Short Circuit, Over-Current
- Surge Protection (8KV): ( IEC 61000-4-2, Contact) Ethernet: 8 Pin Common Mode Protection, 16.5V Clamping Voltage 20A (8/20µs) Peak Pulse Current, <0.8pF
- Shunt Capacitance AC Input: Operating voltage = 385VDC, Clamping voltage = 775VDC, Maximum discharge current is 1200A(8/20us)
- EMC Standards: FCC Class B EN55022 Class B
- Safety Standards: UL1950, CSA 22.2 & TUV EN60950
- Environmental Standards: RoHs
- Operating Temperature: -40 to +60°C (-40 to +140°F)
- Operating Humidity (RH): 5% - 90%
- MTBF (Mean Time BetweenFailure): 44,723 Hours
- Storage Temperature: -40 to +85°C (-40 to +185°F)