PRODUCT SPECIFICATIONS
The TP-POE-HP-56G-FBN Power over Ethernet Power Source offered by Tycon Power is a quality midspan power source for years of reliable operation even in the toughest conditions. They accept data-in to a shielded RJ45 Jack and provide surge protected data-out and power on the shielded RJ45 output jack. They work by supplying power to the remote device on all 8 Ethernet pins. The Ethernet spec supports distances up to 100m (328 feet).
The units are autoranging so that they accept AC inputs from 90VAC to 264VAC (50/60 Hz) and they supply regulated DC Voltage at the output. They have various protections for surge, short circuit, overload and overvoltage. The TP-POE-HP-56G-FBN has an output power of 60watts. The output voltage is 56VDC with load regulation within 5%. The units can be DIN rail mounted.
Features
- Remotely Power Equipment thru CAT5/6 Cable up to 100m
- Built in Ethernet and AC Surge Protection
- Autoranging Switching Power Supply
- Short Circuit, Over Current and Over Voltage Protection
- High Power to 60W PoE Output
- 10/100/1000Mb Gigabit Compatible
- High Temperature Operation to 60C
- DIN Rail Mountable
- I.T.E. Power Supply, UL Listed
Applications
- Wireless Access Points and Client Devices
- IP Phone and Security Camera Systems
Dimensions (LxWxH)
- 125 x 75 x 38mm (4.9 x 3 x 1.5”)
Weight
- 300g (10.6oz)
Technical Description
- AC Input 90-264VAC 47-63Hz
- Max Inrush Current (120VAC) 25A
- POE Voltage 56VDC @ 1.07A
- Output Power 60W Max
- Efficiency (min) 80%
- Line / Load Regulation 1% / 5%
- Ripple / Noise 1% / 2%
- POE Compatibility Passive PoE
- Data Compatibility 10/100/1000M , Gigabit Compatible
- Protections Over-Voltage, Short Circuit, Over-Current
- Surge Protection (8KV) ( IEC 61000-4-2 , Contact) Ethernet: 8 Pin Common Mode Protection, 16.5V Clamping Voltage 20A (8/20µs) Peak Pulse Current, <0.8pF Shunt Capacitance AC Input: Operating voltage = 385VDC, Clamping voltage = 775VDC, Maximum discharge current is 1200A(8/20us)
- EMC Standards FCC Class B EN55022 Class B
- Safety Standards UL1950, CSA 22.2 & TUV EN60950
- Environmental Standards RoHs
- Operating Temperature -40 to +60°C (-40 to +140°F)
- Operating Humidity (RH) 5% - 90%
- MTBF (Mean Time Between
- Failure) 44,723 Hours
- Storage Temperature -40 to +85°C (-40 to +185°F)