PRODUCT SPECIFICATIONS
The TP-DCDC-1248M offered by Tycon Power is a low cost and high reliability solution for those requiring 48VDC Power over Ethernet voltage from a 12 or 24V battery system. They have an integrated POE injector to apply the 48VDC to the CAT5/6 Ethernet cable. The output is regulated 18V, 24V or 48VDC from an input voltage between 9VDC and 36VDC. They have a common (-) and two (+) for connecting 2 power sources, such as a primary with a backup power source. A metal enclosure model is available for industrial applications.
They accept data-in to a shielded RJ45 Jack and provide data-out and POE power on the shielded RJ45 output jack. They work by supplying power on the unused Ethernet pins 4,5(V+) and 7,8(V-).They have various protections for surge, short circuit and overload.
The DCDC converters are DIN rail mountable using DIN Rail adaptors - Model: DIN-ClipKit-UNI
Features
- Input Voltage 9-36VDC; Output 48VDC Passive
- Dual Inputs for connecting 2 power sources
- Integrated 10/100MB POE Inserter
- High Power up to 24W
- Short Circuit, Over Current and Reverse/Over Voltage Protection
- High Temperature Operation
- Compact size – Maximize Available Space
- I.T.E. Power Supply
Applications
- 12V / 24V Battery Systems
- Wireless Access Points and Client Devices
- IP Phone and Security Camera Systems
Dimensions (LxWxH)
- 85 x 76 x 36mm (3.4 x 3 x 1.4”)
Weight
- 134g (4.7oz)
Technical Description
- DC Input Voltage: 9VDC – 36VDC
- DC Input Connector: Removeable Screw Type Compression Wire Terminal (12 AWG Max)
- DC Output Voltage (+/-2.5%): 48V (Passive)
- Data in & Data/POE Output Connector: RJ45 (Shielded)
- Output Current (max): 0.5A
- Output Power (max): 24W
- Self Consumption Power: 1W
- Efficiency (min): 75%
- Line Regulation: 1%
- Load Regulation: 5%
- Ripple: 1%
- Noise: 1%
- EMC Standards: FCC Part 15 Sub B Class A, CE 55032, 55035
- Safety Standards: EN/IEC 60950
- Operating Temperature: -30 to +60°C (-22 to +140°F)
- Operating Humidity (RH): 5% - 90%
- Storage Temperature: -40 to +80°C (-40 to +176°F)
- MTBF (Mean Time Between Failure): 166,000 Hours