null

Tycon Power Systems

Part:
TP-DCDC-2424GR-VHP

Tycon 18-36VDC IN. 24V 70W 4 pair Hi Power Passive PoE OUT. DC to DC Converter and Gigabit PoE Injector. PoE Pins 1245(+) 3678(-)

$129.00
Condition:
New

PRODUCT SPECIFICATIONS

The Gigabit compatible TP-DCDC-2424GR-VHP is a special very high power DC to DC converter / PoE inserter designed especially for Ubiquiti airFiber x wireless radio systems and other systems which require high power passive PoE (High PoE). The unique PoE inserter supplies 24VDC PoE power on all 8 Ethernet wires (4 pair) with the following pinout: 1,2,4,5 V+ and 3,6,7,8 V

They have two common (-) and two (+) for connecting 2 power sources, such as a primary with a backup power source. They have various protections for surge, short circuit and overload. The input and output are isolated.
The units are DIN rail mountable with available adapters: Model: DIN-ClipKit-Uni

Features

  • Input Voltage 24VDC (18-36VDC)
  • 8 wire 24VDC Passive PoE Output
  • High Power Output to 70W
  • Dual DC Inputs for Connecting 2 Power Sources
  • Gigabit Data Thruput
  • Low self consumption power (<2W)
  • Short Circuit, Over Current and Reverse/Over Voltage Protection
  • Industrial Temperature Range
  • I.T.E. Power Supply, UL Listed

Applications

  • 24VDC Remote Power Systems
  • Ubiquiti airFiber x Radios

Dimensions (LxWxH)

  • 125 x 75 x 38mm (4.9 x 3 x 1.5”)

Weight

  • 255g (9oz)

Technical Description

  • Input Voltage +/- 18VDC to 36VDC
  • DC Input Connector Removeable Screw Type Compression Wire Terminal (12 AWG Max)
  • POE Specification Passive PoE ( 8 Wire , 4 Pair )
  • PoE Pinout 1,2,4,5 V+ and 3,6,7,8 VOutput Voltage (+/-2.5%) 24VDC
  • Data in & Data/POE Output Connector RJ45 (Shielded), Shield is connected to FG (Frame Ground) Input
  • Output Current (max) Up to 2.9A
  • Output Power (max) 70W Total Note: Output power up to 70W at 40C. Derate by 1W for every 1 Deg C above 40C ambient. Example: 60W at 50C
  • Self-Consumption Power 2W
  • Efficiency (min) 85%
  • Line Regulation, Ripple, Noise 1%
  • Load Regulation 5%
  • EMC Standards FCC Class B EN55022 Class B
  • Safety Standards CSA 22.2 &TUV EN60950
  • Operating Temperature -40 to +70°C (-40 to +158°F)
  • Operating Humidity (RH) 5% - 90%
  • MTBF (Mean Time Between Failure) 55,489 Hours
  • Storage Temperature -40 to +80°C (-40 to +176°F)

More Information

MFRPartNum:
TP-DCDC-2424GR-VHP
Datasheet: