null

Tycon Power Systems

Part:
TP-DCDC-A2456GD-BT

Tycon 22-35VAC/DC IN. 56V 90W 802.3bt PoE OUT. AC/DC to DC Converter and Gigabit 802.3bt PoE Injector

$227.95
$239.95
Condition:
New

PRODUCT SPECIFICATIONS

The TP-DCDC-A2456GD-BT is a 5Gbps high power DCDC converter and PoE injector that accepts 22-35VAC or VDC input. It features a wide operating temperature range (-40 to +70C) and a high power 802.3bt 90W output. 

The unit has dual AC/DC inputs for maximum flexibility. The green DC connector accepts wires up to 12AWG. The “FG” input is used to provide chassis or earth ground. 

The device is fan-less and uses natural air flow for cooling. It comes with DIN rail adapters to provide mounting to a standard DIN Rail commonly used in industrial installations. It can also be wall mounted.

Features 

  • 22-35VAC/VDC Input, 802.3bt 90W Output 
  • Industrial Temperature Range: -40 to +70C 
  • Up to 5Gigabit Data Passthru with Surge Protection 
  • DIN Rail Mounting (Adapters Included)

Applications 

  • 802.3bt PoE from Legacy 24VAC Power Sources
  • 24VDC Remote Power Systems 
  • IEEE802.3bt Industry Standard Device Power from Batteries
  • PoE Lighting Applications

Dimensions (LxWxH)

  • 140 x 150 x 40 mm (5.5” x 5.9” x 1.6”)

Weight

  • 0.66kg (1.45lb)

Technical Description

  • Input Voltage: 22 to 35VAC 50/60hz or 22 to 35VDC
  • Input Current: 
    • 4.42A @ 24VAC IN (Full Load)
    • 4.40A @ 24VDC IN (Full Load)
  • Output Voltage: IEEE802.3bt 56VDC ; Load Reg = 5%, Line Reg = 1%
  • Output Current / Max Watts: 1.6A / 90W
  • Ripple & Noise: 1%
  • Efficiency: >80% 22-35V Input
  • Protections: Short Circuit, Reverse Voltage
  • Over Current Protection: 802.3bt Limits ; Auto Recover
  • Low Voltage Detect (LVD): Device with stop drawing all current when input voltage drops below 33.2VDC
  • Misc Protections: Short Circuit, Reverse Voltage
  • Data PassThrough: 10/100/1000/5000Mbps ; Gigabit
  • Data Protection:
    • Pin to Pin (1-2, 3-6, 4-5, 7-8)
    • Clamp Voltage: 3.3V
    • ESD, IEC61000-4-2: +/- 30KV contact and air
    • EFT, IEC61000-4-4: 40A (5/50us)
    • Lightning, IEC61000-4-5: 15A (8/20us)
  • MTBF: 135,326 Hrs
  • Safety Standards: TUV EN62368-1
  • EMC Standards: FCC Class B ; EN55032 Class B
  • Connections: Removable Wire Terminal
  • Wire Size: 12AWG Max
  • LED Function: 
    • Green Power LED = Valid 802.3bt Detection
    • Red STB LED = Input Power OK
  • Mounting: Wall Mount or DIN Rail (Adapters Included)
  • Operating Temperature: -40C to +70C (-40F to 158F)
  • Humidity (RH): 5% - 90% Non-Condensing

More Information

MFRPartNum:
TP-DCDC-A2456GD-BT
Datasheet: