PRODUCT SPECIFICATIONS
Ubiquiti UA-Hub-Door-Mini
Compact Access Control Hub for a single door.
Key Features
- PoE out for readers
- 12V and dry switch
- Exit request input terminal
- Lock terminal (12V and dry switchable)
- Input for door position sensors
- DIN rail mount
- GbE, PoE++ in RJ45 port
- (2) GbE, PoE out RJ45 ports
- Overview:
- Dimensions: 113 x 66 x 27.6 mm (4.4 x 2.6 x 1.1')
- UniFi Application Suite:
- Access: ✓
- Supported Doors: 1
- Input Terminals:
- (1) Door exit request
- (1) Door position
- Power Method:
- PoE++
- UL 294 Power-limited Class 2 PSU
- UL 60950-1/62368-1 LPS/PS2 PSU
- NDAA Compliant: ✓
- UL 294 Level:
- Destructive attack: Level I
- Line security: Level I
- Endurance: Level I
- Standby power: Level I
- Mechanical:
- Weight: 190 g (6.7 oz)
- Enclosure Material: Polycarbonate, metal
- Mounting: DIN-rail (Included)
- Hardware:
- Dry Output Relay: 30V DC, 1A
- Indoor and Outdoor Use: Indoor only
- Ambient Operating Temperature: 0 to 40° C (32 to 104° F)
- Ambient Operating Humidity: 5 to 90% noncondensing
- Networking Interface:: (3) GbE RJ45 ports
- PoE Interface:
- (1) PoE++ input, 50V DC, 1A
- (2) PoE outputs, total 31W
- Max. Power Consumption:
- 19W (Without PoE output)
- 50W (With PoE output)
- LEDs:: W/B Learn More
- Buttons:
- (1) Factory-reset
- (1) Dry/Wet switch
- Recommend Max. Cable Length:
- UA-Lock-Electric (400mA):
- 24 AWG length: 25 m (82 ft)
- 22 AWG length: 42 m (138 ft)
- 20 AWG length: 66 m (217 ft)
- 18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
- UA-Lock-Magnetic-540kg (500mA):
- 24 AWG length: 12 m (29 ft)
- 22 AWG length: 20 m (66 ft)
- 20 AWG length: 30 m (98 ft)
- 18 UACC-Cable-DoorLockRelay length: 46 m (262 ft)
- UA-Lock-Magnetic-270kg (800mA):
- 24 AWG length: 12 m (29 ft)
- 22 AWG length: 20 m (98 ft)
- 20 AWG length: 30 m (167 ft)
- 18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
- Other locks (1A):
- 24 AWG length: 9 m (30 ft)
- 22 AWG length: 15 m (49 ft)
- 20 AWG length: 24 m (79 ft)
- 18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
- UA-Lock-Electric (400mA):
- PoE Cabling Requirements:
- Cat 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
- The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
- UL 294 Statement:
- Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
- The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
- CAN/ULC-60839-11-1 Grade: Grade assignment: I
- Certifications: CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
- Document number, and issue date and/or revision level: UA-Hub-Door-Mini, V01
- Software:
- Management Application: Access
- Software Information: The software version can be checked at https://unifi.ui.com