null

Ubiquiti

Part:
EAH-8-US

Ubiquiti Enterprise Access Hub (US Version)

$999.00
Condition:
New

PRODUCT SPECIFICATIONS

Enterprise-grade access hub with entry and exit control up to eight doors and battery backup support.

  • (8) Lock terminals (12V or Dry)
  • (8+8) Inputs for request-to-exit devices and door position sensors
  • (8) PoE ports for Access Readers
  • (4) AUX terminals for chimes, sirens, or door openers
  • (1) Battery backup input (32–48V)

Technical Description

  • Mechanical
    • Dimensions: 379 x 355 x 105 mm (15 x 14 x 4.1")
    • Weight: Device: 9.1 kg (20 lb)
    • Mount: 624 g (1.4 lb)
    • Enclosure material: SGCC housing with PC cover
    • Mounting material: SGCC wall mount plate
  • Hardware
    • Networking interface: (10) 10/100/1000 Base-T
    • Power method:
      • Universal input, 100–240V AC, Max. 4.4A, 50/60Hz
      • 32–48V DC Lead Acid Battery, Max. 7.5A @32V
    • Power supply: AC/DC, internal
    • Max. power consumption: 240W
    • PoE interface: (8) PoE (Pins 1, 2+; 3, 6-)
    • Voltage range PoE mode: 44–57V DC
    • Total available PoE: 60W
    • Max. PoE wattage per port: 15.4W
    • LEDs:
      • System: white/blue
      • Output relays: steady white
      • Ethernet: flashing white
    • Button: (1) Factory-reset
    • Digital input:
      • (8) Inputs for request-to-exit devices
      • (8) Inputs for door position sensors
      • (1) Emergency
    • Dry output relay:
      • (8) Lock terminals (12V or Dry)
      • (4) AUX terminals for advanced setup (Chime/Siren/Door opener)
    • Powered output relay:
      • Lock: 12V DC, 1A/ Dry
      • Aux: Dry only
    • Operating environment: Indoor use only
    • Ambient operating temperature: 0 to 40° C (32 to 104° F) 
    • Ambient operating humidity: 5 to 95% noncondensing
    • Software information: The software version of a product can be checked at https://unifi.ui.com
    • UL 294 level:
      • Destructive attack: Level I
      • Line security: Level I
      • Endurance: Level I
      • Standby power: Level I
    • UL 294 statement:
      • Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
      • The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
    • PoE cabling requirements: 
      • Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
      • The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm2) for patch cords; 24 AWG (0.21 mm2) for horizontal or riser cable.
    • CAN/ULC-60839-11-1 Grade: Grade assignment: I
    • Certifications: CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
    • Document number, and issue date and/or revision level: EAH-8, Ver 01
  • LED
    • System:
      • Steady blue: adopted, device is ready
      • Steady white: pending adoption
      • Blinking white/blue: upgrading firmware
      • Breathing white: system initiating
  • Software
    • Management application: UniFi Access: Version 1.22.17 and later

More Information

MFRPartNum:
EAH-8-US
Quick Installation Guide: